How To Replace Thermocouple On Gas Fireplace

How do you change a thermocouple on a gas fireplace?

Procedure for Replacing a Thermocouple Turn off the gas supply to the gas valve. Use the wrench to unscrew the connector that holds the thermocouple to the gas valve, then unhook the probe from its clip and pull out the entire thermocouple assembly. Take the thermocouple to the hardware store to purchase a new one.

Can you replace a thermocouple yourself?

1 cause of pilot lights that won’t stay lit is a worn-out thermocouple. It’s easy to replace and a new one costs $5 to $10. Then detach the thermocouple from the burner and take it with you to the home center or hardware store to ensure you buy the right replacement.

How do I know if my thermocouple is bad on my gas fireplace?

The Fix: Pilot Light to Gas Fireplace Won’t Stay Lit So you’ve checked your pilot light and even reset it, but still, it wont stay lit. This can be an indication that your fireplace thermocouple is either bad or worn out.

How much does it cost to replace a thermocouple in a gas fireplace?

When replacing a thermocouple or thermopile with the help of a professional, you can expect to pay between $150 and $250.

How long does a fireplace thermocouple last?

Thermocouples can last up to 10 years if properly installed and maintained, while furnaces can last 15-20 years, although either may wear out sooner in multifamily units.

Are thermocouples universal?

Honeywell, White Rodgers, and other manufacturers make universal replacement thermocouples, usually with a 30-millivolts (mV) rating for standing-pilot furnaces. Electronic flame sensors are much less universal, and you must find the exact part specified for your furnace model.

Can you clean a thermocouple?

Yes, you can clean a thermocouple, but the task must be done with a light touch. Remove the thermocouple from the process assembly, using a steel wool or emery cloth, lightly clean the tip removing any build up.

What makes a thermocouple go bad?

Soot buildup on the thermocouple may block the flame. Under constant exposure to a hot flame, a thermocouple wears down over time. Even a slight residue can make the thermocouple malfunction.

How do you troubleshoot a thermocouple?

Importantly, always make sure the tip of the thermocouple is directly in the pilot flame. If the tip is in the flame, you have held the nob on the gas valve down for longer than a minute, the pilot flame is strong and steady, and the pilot still does not stay lit, then you likely have a problem with the gas valve.

How much does it cost to replace a thermocouple?

It costs $150 to $250 to replace a thermocouple. It checks to make sure the pilot light is on. It will shut the gas off if it’s not.

Why will my gas fireplace not stay lit?

The thermocouple and thermopile are the two most common reasons why a gas fireplace won’t stay lit. However, there are other possibilities out there. Another common culprit is incorrect gas pressure. As the seasons pass, you may find that your gas pressure drops below where it needs to be.

Why won’t my pilot light stay lit in my gas fireplace?

If the pilot light on your gas fireplace won’t stay lit, a very likely culprit is a component called a thermocouple. A thermocouple is a safety device and is a component of the ignition system. Its purpose is to not allow the gas valve to open if the pilot light isn’t lit.

Where is the thermocouple located on a gas fireplace?

Find the thermocouple, which is located next to the pilot light and looks like a small straight pipe.

Should thermocouple be in pilot flame?

The pilot flame should touch the thermocouple at a specific level. If the flame is blue and weak, and barely reaches the thermocouple, it needs to be stronger. If it extends well above the thermocouple, it’s too strong. Install a new thermocouple by screwing it in, heating it up a bit, and then lighting the pilot.

What happens if a thermocouple fails?

Normally when the thermocouple malfunctions or isn’t working, it simply shuts off the gas to your heater. This is important, particularly if the pilot light is out, because it prevents harmful gas from leaking into your home.

Can thermocouples go bad?

Like the other component parts in your furnace, the thermocouple can wear down over time, producing lower voltage than it should when heated. And the worst part is that you can have a bad thermocouple without even knowing. Therefore, inspecting and testing your thermocouple should be part of your furnace maintenance.

How do you override a thermocouple?

To bypass the thermocouple: Move the tilts switch wire aside. Remove your thermocouple from the heater using an 8mm wrench. Pull the valve housing aside using your 13mm socket wrench. Remove the valve using your pliers. Put your thermocouple back into position.

Are all gas thermocouples the same?

From an operational perspective the thermocouples for a water heater are all pretty much the same. However, there are two variables, the length and the fittings used to install them, see below. A failing thermocouple will not send the correct electrical impulse and the gas valve will not release any gas.

How do I know what kind of thermocouple I need?

How to choose a Thermocouple Determine the application where you will use the thermocouple sensor. Determine the temperature ranges the probe will be exposed to. Determine how important a fast response time is. Consider any chemical, abrasion or vibration resistance. Consider any installation requirements.

Can I use any thermocouple?

Watch out: thermopiles and thermocouples are not interchangeable. When replacing a temperature sensing device like a thermocouple or thermopile, you should be sure to purchase the proper part.